Qty:
Feature:
Application: It can be used in
Wireless remote control, easy to install.
Waterproof: The receiver has
Power Supply: Four working voltage versions, DC 6V, 9V, 12V, 24V.
DC Power Output: It can control DC equipment with voltage DC 6V / 9V / 12V / 24V.
High Power: Each channel can work at maximum current 30A, such as 360W/12V, 180W/6V, 270W/9V or 720W/24V.
With wired control terminals: You can connect sensors, limit switches, manual switches or external devices to control the receiver.
You can control the
Wireless RF signal can pass through walls, floors, doors or windows.
With characteristics of reverse power protection and
Reliable control: The code has thousands of different combinations, and the receiver only works with the transmitter which
One/several transmitters can control one/several receivers simultaneously.
You can use two or more units in the same place.
Transmitter Parameters:
Model No.: 0021001 (C-2)
With Sliding Cover: Slide up when it doesn’t work (to protect the button). Slide down the button will appear.
Channel/Button: 2
Button Symbol:1, 2
Operating Voltage: 12V (1 x 23A -12V battery, can be used for 12 months)
Operating Current: 6mA
Operating Frequency: 433Mhz
Modulation Mode: ASK
Unit Size: 58mm x 39mm x 16mm
Receiver Parameters:
Model No.: S1PX-DC06 / S1PX-DC09 / S1PX-DC12 / S1PX-DC24
Power Supply (Operating Voltage): DC6V (S1PX-DC06), DC9V±1V (S1PX-DC09), DC12V±1V (S1PX-DC12), DC24V±2V (S1PX-DC24)
Output: DC6V (S1PX-DC06), DC9V (S1PX-DC09), DC12V (S1PX-DC12), DC24V (S1PX-DC24)
Wire range for the terminals: 22-9 AWG
Working Frequency: 433MHz
Channel: 1 CH
Control Modes: Self-locking, Momentary, Interlocking
Static Current: ≤6mA
Operating Temperature: -20 ° C to +70 ° C
Maximum Working Current: 30A
PCB size: 90mm x 59mm x 18mm
Case size: 100mm x 68mm x 50mm
Matching Transmitters For Receiver:
The receiver can work with different transmitters, such as model C-1 / C-2 (100M), CWB-1 / CWB-2 (50M, waterproof), CP-1 / CP-2 (500M), or CB-1 / CB-2 (1000M) etc.
When you set the receiver in toggle or momentary mode, it should work with single button
Working Range:
With a transmitter (such as C-2) to form a complete set, the maximum working distance can reach 100M in an open ground.
The maximum working distance is an ideal
If you want to have a further working range, you can install an external antenna to the receiver, and you also can use a powerful transmitter, such as CB series transmitters.
Usage (with the transmitter C-2):
The receiver can be used to control DC 6V / 9V / 12V / 24V
Wiring:
If you want to control a DC 12V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “L / +” of INPUT, and connect the negative pole of DC power supply to terminal “N / -” of INPUT.
2) Connect the positive pole of
Setting different control modes:
We have set the receiver in toggle mode before
1) Setting control mode Self-locking: Only connect Jumper-2.
Control mode Self-locking (with transmitter C-1): Press -> On; Press again -> Off.
Press button of the transmitter: Output terminals
Press button again: Output terminals stops outputting, and the lamp is turned off.
2) Setting control mode Momentary: Only connect Jumper-1.
Control mode Momentary (with transmitter C-1): Press and hold -> On; Release -> Off.
Press and hold
Release button of the transmitter: Output terminals
3) Setting control mode Interlocking: Do not connect Jumper-1 and Jumper-2.
Control mode Interlocking (with transmitter C-2): Press -> On, Press another button -> Off.
Press button A of the transmitter: Output terminals
Press button B of the transmitter: Output terminals
Wired control terminals:
The receiver has wired control terminals, and you can connect external devices, sensors, or manual switches to the receiver's manual terminals, then use them to trigger the receiver.
1) By
You can connect external devices (with
When external device outputs
When external device stops to
2) By NO/NC contact:
You can connect manual switches (with NO/NC contact) to trigger the receiver.
When connect terminals 1 and 2 by
When disconnect terminals 1 and 2 by