Operating Temperature: -20 ° C to +70 ° C
PCB size: 67mm x 50mm x 18mm
Case size: 75mm x 54mm x 27mm
Transmitter Parameters:
Model No.: 0021000 (C-1) / 0021001 (C-2)
With Sliding Cover: Slide up when it doesn’t work (to protect the button). Slide down the button will appear.
Channel/Button: 1 (C-1) / 2 (C-2)
Button Symbol: No symbol (C-1) / 1, 2 (C-2)
Operating Voltage: 12V (1 x 23A -12V battery, can be used for 12 months)
Operating Current: 6mA
Operating Frequency: 433.92Mhz
Encoding Chip: PT2262/ PT2264/ SC2262
Encoding Type: Fixed code by soldering, up to 6561 codes.
Transmitting Distance: 100m / 300ft (theoretically)
Modulation Mode: ASK
Unit Size: 58mm x 39mm x 16mm
Matching Transmitters:
The receiver can work with different transmitters, such as model C-1 / C-2
(100M), CWB-1 / CWB-2 (50M, waterproof), or CB-1 / CB-2 (1000M) etc.
When you set the receiver in Self-locking or Momentary mode, it should work
with single button transmitter, such as model C-1 (100M), CWB-1 (50M,
waterproof), or CB-1 (1000M) etc. When you set the receiver in Interlocking
mode, it should work with two buttons transmitter, such as model C-2 (100M),
CWB-2 (50M, waterproof), or CB-2 (1000M) etc.
Working Range:
With a transmitter (such as C-2) to form a complete set, the maximum working
distance can reach 100M in an open ground.
The maximum working distance is a theoretical data, it shall be operated in
an open ground, no barriers, no any interference. But in the practice, it
will be hindered by trees, walls or other constructions, and will be
interfered by other wireless signals. Therefore, the actual distance may not
reach this maximum working distance.
If you want to have a further working range, you can use a powerful
transmitter, such as CB-1 or CB-2 transmitter.
Usage (with the transmitter C-1 or C-2):
The receiver can be used to control both DC 0~28V and AC 110~240V
equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state
of relay output terminals: Terminals B and C are Normally Open; Terminals A
and B are Normally Closed.
Wiring:
If you want to control a DC 12V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “L / +” of
INPUT, and connect the negative pole of DC power supply to terminal “N / -”
of INPUT.
2) Connect terminal C to the positive pole of DC power supply, connect
terminal B to the positive pole of DC lamp, and connect the negative pole of
DC lamp to the negative pole of DC power supply.
If you want to control an AC 220V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal “L / +” of
INPUT, and connect the negative pole of DC power supply to terminal “N / -”
of INPUT.
2) Connect terminal C to the live wire of AC power supply, connect terminal
B to one side of AC lamp, and connect another side of AC lamp to the neutral
wire of AC power supply.
Setting different control modes:
Setting different control modes (We have set the receiver as Self-locking
control mode before delivery. If you want to use other control modes, do as
following operation):
1) Setting Self-locking mode: Only connect Jumper-2.
Mode Self-locking (working with transmitter C-1): Press -> On; Press again
-> Off.
Press the button of the transmitter: The relay is activated (connect the
terminals B and C, disconnect the terminals A and B), and the lamp is turned
on.
Press the button again: The relay is deactivated (disconnect the terminals B
and C, connect the terminals A and B, and the lamp is turned off.
2) Setting Momentary mode: Only connect Jumper-1.
Mode Momentary (working with transmitter C-1): Press and hold -> On; Release
-> Off.
Press and hold the button of the transmitter: The relay is activated
(connect the terminals B and C, disconnect the terminals A and B), and the
lamp is turned on.
Release the button: The relay is deactivated (disconnect the terminals B and
C, connect the terminals A and B, and the lamp is turned off.
3) Setting Interlocking mode: Disconnect Jumper-1 and Jumper-2.
Mode Interlocking (working with transmitter C-2): Press -> On; Press another
button -> Off.
Press the button 1 of the transmitter: The relay is activated (connect the
terminals B and C, disconnect the terminals A and B), and the lamp is turned
on.
Press the button 2 of the transmitter: The relay is deactivated (disconnect
the terminals B and C, connect the terminals A and B, and the lamp is turned
off.